CT-100S Conductivity / TDS Transmitter is a reliable, two-wire loop-powered transmitter designed for accurate online conductivity and TDS measurement in industrial and process applications. It accepts conductivity electrodes with cell constants 0.01, 0.1, and 1, converting the measured signal into a stable 4–20 mA output with optional HART communication. The transmitter features a backlit LCD display for real-time indication and offers auto or manual temperature compensation using RTD PT-100 / PT-1000. With high accuracy of ±0.25% of full scale, fast response time, and low power consumption, CT-100S ensures dependable performance. Its non-volatile memory retains settings during power failures, enhancing operational reliability. Housed in weatherproof IP67 or CMRI IIA/IIB flameproof enclosures, CT-100S is ideal for water treatment, chemical, pharmaceutical, and industrial process monitoring applications.
Configure the transmitter and electronics based on application, environment, and compliance requirements.
| Parameter | Specification |
| Electronics Transmitter Accuracy | ±0.25% F.S. |
| Isolation | 1.4 KV between Input, Output & Power Supply |
| Display | Local LCD Display with Backlit |
| Output Type | 4–20 mA DC / 4–20 mA with HART (Generic) |
| Sensor Connection | 1) BNC Connector 2) Terminal Connection |
| Power Supply | 24 V DC Two Wire Loop Powered |
| Power Consumption | < 50 mW |
| Electronic Protection Class | Flameproof CMRI IIA IIB / Weatherproof IP-67 |
| Response Time | < 500 mSec |
| Temperature Coefficient | ±0.01 % per °C |
| Temperature Compensation | RTD PT-100 / RTD PT-1000 |
| Dimensions | 155 mm (H) × 105 mm (W) × 130 mm (D) |
| Conduit Entry | 1) M20 × 1.5 (F) 2) ½” NPT (F) |
| Mounting | 2” Pipe Mounting |
| Weight | Approx. 1 kg |
| Housing | Cast Aluminium with Epoxy Coating / SS316 (NEMA 4X) |
| Ambient Conditions | Temp. -20 to 70 °C, Humidity 5–95% Non-condensing |
| Cell Constant | 0.01 / 0.1 / 1 |
| Input Type | From Conductivity Electrode |
| Calibration | Factory
Calibrated - 1) 0 to 999.99 μS/cm for cell constant
0.1 |
| 2) 0 to
99.99 μS/cm for cell constant 0.01 |
|
| 3 ) 0 to 9999.99 μS/cm for cell constant 1 |
Download the complete product catalogue for detailed specifications, dimensions, certifications, and application guidance.
Electronet instruments are widely deployed across multiple industries and utilities for reliable monitoring and control of critical process parameters.
| Industry | Key Applications |
| Water & Wastewater | Monitoring conductivity and TDS in treatment plants, pipelines, and effluent systems |
| Chemical & Petrochemical | Measuring solution concentration, process water quality, and chemical dosing accuracy |
| Power Generation | Conductivity monitoring in boiler feedwater, cooling water, and condensate systems |
| Food & Beverage | Monitoring water quality and process liquids for production consistency and safety |
| Pharmaceuticals & Biotechnology | Conductivity/TDS monitoring in process water, bioreactors, and formulation systems |
| Pulp & Paper Industry | Monitoring chemical concentrations and water quality in pulping and bleaching processes |
| Marine & Shipbuilding | Conductivity/TDS measurement in seawater systems, ballast, and cooling circuits |
| Metals & Mining | Monitoring process water and slurry conductivity for process optimisation |
| HVAC & Building Automation | Water quality monitoring in cooling towers and chilled water systems |
| Semiconductor & Electronics | Conductivity/TDS monitoring for ultra-pure water and process control |
Core capabilities and advantages of the product.