ELMAG TX-22 Two-Wire Electromagnetic Flow Meter is a microcontroller-based, full-bore flow measurement solution designed for conductive liquids and slurries in closed pipelines. Operating on Faraday’s Law with Pulsed DC excitation, it delivers accurate and stable flow measurement with minimal power consumption through a 2-wire 4–20 mA loop-powered system. The obstruction-less design ensures zero pressure loss and maintenance-free operation, making it a reliable alternative to mechanical flow meters. ELMAG TX-22 supports pipe sizes from 15 NB to 300 NB and offers accuracy up to ±0.5% of measured value. Features such as empty pipe detection, local LCD indication, HART compatibility, and rugged IP67/IP68 protection make it ideal for water, wastewater, and industrial process applications. Its simple, cost-effective construction ensures long-term performance in demanding field conditions.
Configure the transmitter and electronics based on application, environment, and compliance requirements.
|
Media |
Liquids (Conductive) |
|
Line Size |
15 NB to 300 NB |
|
Electronics |
Integral |
|
Power Supply |
24V DC |
|
Power Consumption |
40 mw |
|
Conductivity |
> 5 µs/cm |
|
Viscosity |
200 cp max |
|
Excitation |
Pulsed DC
Coil |
|
Type of Output |
4 to 20mA DC,
4 to 20mA DC with HART |
|
Display |
LCD display - 5 Digit
for Flow Rate and 8 Digit for Totalizer Flow |
|
Engineering Unit |
User Programmable (m3/hr by
default) |
|
Calibration |
Wet Calibrated at IEC/ISO/EN17025 Accredited Calibration Laboratory. |
|
Accuracy |
< ± 0.5% of M.V. +(± 5mm /sec)
for Velocity Range
0.3 m/s to 6 or 12 m/s |
|
Flow Velocity Range |
0.3 m/s to + 6 m/s |
|
Velocity |
0.3 m/s - 2.5m/s
upto Max. 10m/s |
|
Linearity |
+/- 0.5%
of M.V. |
|
Repeatability |
+/- 0.2%
of M.V. |
|
Temperature Coefficient |
+/- 0.1%
per °C |
|
Process Temperature |
-20 to 85° C max for Rubber Lining
& -20 to 220°C for PTFE Lining |
|
Process Pressure |
16 kg/cm2 max (Higher on request) |
|
Material of construction |
1) Lining
- Neoprene / Ebonite Rubber, PFA, PTFE, PU, CERAMIC |
|
2) Flange - MS, CS, SS316, SS304
& PVC |
|
|
3) Electrode - SS316L, Hastelloy C, Platinum, Tantalum, Titanium |
|
|
4) Coil
Housing - MS, SS304, SS316 & PVC |
|
|
Isolation |
1.4 KV between Input,
Output and Power
Supply |
|
Response Time |
< 10 Sec. |
|
Electronic Protection Class |
Field Mount Weather
Proof IP-67 |
|
Field Mount Weather
Proof IP-68 |
|
|
Sensor / Flow Tube
Protection class |
Weather Proof IP-68 |
|
Process Connections |
ANSI150 flanged, as per table
B 16.5 (Other
On Requirement) |
|
Mounting |
In-Line Horizontal / Vertical |
|
Ambient Conditions |
Temperature -20 to 70°C
/ Humidity 5 to 95% non condensing |
Download the complete product catalogue for detailed specifications, dimensions, certifications, and application guidance.
Electronet instruments are widely deployed across multiple industries and utilities for reliable monitoring and control of critical process parameters.
| Industry | Key Applications |
| Water & Wastewater | Flow measurement in pipelines, treatment plants, and pumping stations with two-wire low-power operation |
| Chemical & Petrochemical | Monitoring conductive liquid flow in reactors, storage tanks, and pipelines with minimal wiring requirements |
| Food & Beverage | Flow measurement in production lines, tanks, and process liquids with simple two-wire installation |
| Pharmaceuticals & Biotechnology | Monitoring process liquids in bioreactors, formulation, and CIP systems with low-power two-wire setup |
| Pulp & Paper Industry | Measuring water, chemicals, and slurry flow in pulping and bleaching processes with two-wire configuration |
| Power Generation | Flow measurement in cooling water, boiler feedwater, and condensate pipelines with low-power installation |
| Marine & Shipbuilding | Flow monitoring in fuel, water, and process pipelines using compact two-wire setup |
| Metals & Mining | Measuring slurries and chemical flows in pipelines with simplified wiring requirements |
| HVAC & Building Automation | Flow measurement in chilled water, heating, and cooling circuits using two-wire operation |
| Environmental Monitoring | Flow measurement of treated water, effluents, and process discharges with two-wire simplicity |
Core capabilities and advantages of the product.