The ELCMF-200 Coriolis Mass Flow Meter is an advanced measurement solution designed for accurate and reliable measurement of mass flow, density and temperature in demanding industrial processes. Based on the Coriolis principle, it provides direct and simultaneous measurement of all three parameters through a single sensor, without requiring external pressure, temperature or density compensation for mass flow measurement.
Designed for high-performance industrial applications, the ELCMF-200 offers liquid mass flow accuracy of ±0.2% of reading (optional ±0.1%) and gas mass flow accuracy of ±0.75% of reading. Its robust SS316L measuring tube, IP68 flow tube protection and absence of moving parts ensure reliable operation in challenging process environments.
The meter handles liquids, gases and viscous or particulate-laden slurries, with no upstream or downstream straight-pipe length requirement. Its versatile installation configurations, compact or remote electronics, and multiple output and communication options make it suitable for a wide range of industrial measurement and control applications.
With its high repeatability and dependable measurement performance, the ELCMF-200 is ideal for batching, loading, process monitoring, reactor feed ratio control and precise dosing applications across chemical, oil & gas, marine, pharmaceutical, food & beverage and semiconductor industries.
Configure the transmitter and electronics based on application, environment, and compliance requirements.
| Parameter | Standard Rating | Options |
| Diameter (Line size) | 3 NB to 50 NB | – |
| Flow accuracy — liquid | ±0.2% of reading | ±0.1% |
| Flow accuracy — gas | ±0.5%–1% | – |
| Flow repeatability | ±0.1% of reading | – |
| Zero stability | Refer flow range table (per size) | – |
| Density range | 0.3 to 3.000 g/cm³ | – |
| Density accuracy | ±0.005 g/cm³ | – |
| Temperature measuring range | ‒50°C
to +200°C (standard model) |
−200°C
to +300°C (extended / cryogenic) |
| Temperature Measurement error | ±1°C ± 0.5% of reading | – |
| Nominal pressure rating | 4.0 MPa (580 psi) | – |
| Current output 1 (Flow) | 4–20 mA | 4–20 mA with HART |
| Current output 2 (Density) | Optional | 4–20 mA |
| Frequency/pulse output | 0–10,000 Hz, open-collector | – |
| Digital communication | RS-485, Modbus RTU | – |
| Electrical Output (Alarm & Relay) | – | Two Alarm Contact rating 1/CO, 3 Amp |
| Power supply | 18–36 VDC, < 6 W | 85–265 VAC — confirm at order |
| Flow Tube Ingress Protection class | IP-68 | – |
| Material (Wetted material) | Measuring tube: SS316L | – |
| Housing material | SS-304 | – |
| Ambient temperature | ‒20°C to +70°C | – |
| Environment humidity | 5% to 95% RH, at 25°C | – |
Download the complete product catalogue for detailed specifications, dimensions, certifications, and application guidance.
Electronet instruments are widely deployed across multiple industries and utilities for reliable monitoring and control of critical process parameters.
| Industry | Key Applications |
| Chemical & Petrochemical | Accurate mass flow measurement of liquids and gases in reactors, pipelines, and process systems |
| Oil & Gas | Monitoring crude oil, refined products, and gas flow in pipelines, custody transfer, and storage tanks |
| Food & Beverage | Mass flow measurement in liquid ingredients, syrups, dairy, and beverage production lines |
| Pharmaceuticals & Biotechnology | Monitoring mass flow in bioreactors, formulation, and process lines with high accuracy |
| Water & Wastewater | Measuring flow of chemicals, process liquids, and dosing systems in treatment plants |
| Power Generation | Mass flow measurement of fuel, feedwater, and cooling liquids in thermal power plants |
| Pulp & Paper Industry | Monitoring chemical and water flow in pulping, bleaching, and process lines |
| Metals & Mining | Mass flow measurement in slurries, chemicals, and liquid process streams |
| Marine & Shipbuilding | Monitoring fuel and process liquids in engines, boilers, and storage tanks |
| HVAC & Building Automation | Mass flow measurement in chilled water, heating, and cooling systems for energy monitoring |
Core capabilities and advantages of the product.
Three-in-One Measurement: Simultaneous measurement of mass flow, density and temperature using a single sensor.
High Measurement Accuracy: Liquid mass flow accuracy of ±0.2% of reading (optional ±0.1%) and gas accuracy of ±0.75% of reading.
Direct Mass Flow Measurement: No external pressure, temperature or density compensation required.
Flexible Installation: No upstream or downstream straight-pipe run requirement.
Robust Construction: SS316L measuring tube with IP68 flow tube protection.
Low Maintenance: No moving parts, no wear-related recalibration and minimal routine maintenance.
Versatile Connectivity: 4–20 mA, optional HART, pulse/frequency output and RS-485 Modbus RTU communication.
Flexible Configuration: Integral and remote electronics mounting options.
Wide Process Compatibility: Suitable for liquids, gases, viscous fluids and particulate-laden slurries